Fast, reliable, and intelligent – the ultimate DC charging solution for public and commercial fleets.

The SOLNET 60kW DC Fast Charger (ENC-DCL060A/B) delivers high-power direct current charging for all modern EVs. With a wide output range of 200–1000V, it’s ready for today’s 400V EVs and tomorrow’s 800V architectures. Choose between single or dual gun configurations to maximize station throughput.


⚡ Key Features

  • 60kW output power – fast charging for all EV types

  • 1 or 2 outputs – single or dual gun configuration

  • Wide voltage range – DC 200–1000V (800V ready)

  • Max current – up to 250A

  • High efficiency – ≥95% at nominal output power

  • Power factor – ≥0.99 (full load)

  • 12-inch color touchscreen – 800×480 resolution

  • Nuclear safety grade power module platform – ultra-reliable

  • Advanced digital current sharing – high accuracy & anti-interference

  • Module dormancy & rotation technology – system efficiency optimization

  • Multiple charging modes – automatic, by time, by energy, by cost

  • Real-time display – charged quantity, time, pricing, status

  • Hot plug-in technology – easy maintenance

  • Emergency stop switch – built-in

  • IP54 rated – outdoor weather-resistant

  • Forced air cooling – reliable thermal management

  • OCPP 1.6 protocol – seamless CMS integration

  • Multiple communication options – Ethernet / 3G / 4G / WiFi (optional)


🎯 Applicable Scenes

Scene Application
🚌 City bus charging stations Overnight and opportunity charging
🚕 Taxi depots Quick turnaround between shifts
🚚 Logistics & delivery fleets Fast charging for commercial vans
🗑️ Sanitation & utility vehicles Municipal fleet operations
🅿️ Public charging stations Urban parking lots & plazas
🏢 Shopping centers Attract EV-driving customers
🏘️ Residential districts Shared community fast charging
🛣️ Intercity highways Critical fast-charging infrastructure
🔌 Limited-space sites Compact footprint, maximum power

“Especially suitable for fast charging situations such as charging stations on intercity expressways where DC is needed, particularly in cases of limited sites.”


📦 Technical Specifications

Parameter Details
Charger Capacity 60kW
Model No. ENC-DCL060A / ENC-DCL060B
Input System Three-Phase, 5 Wire AC
Input Voltage AC380V ±15% / AC260–530V
Input Frequency 45–65Hz
Output Type DC 200–1000V
Number of Outputs 1 or 2 (optional)
Max Output Current 250A
Converter Efficiency ≥95% at nominal output power
Power Factor ≥0.99 (full load)
Operating Temp -25°C to +55°C
Humidity 5–95%
Storage Temp -40°C to +70°C
IP Rating IP54
Cooling Forced air cooled
Mechanical Stability As per IEC 61851-1 Section 11.11.2
Connector Compatibility IEC 62196, IEC 61851, CCS-2
Display 12-inch touch screen (800×480)
Emergency Stop Supported
User Authentication QR Code / RFID Card / Password Login
Metering Consumption units, grid-responsive
Communication OCPP 1.6 + Ethernet/3G/4G/WiFi (optional)

🛡️ Protection Functions

  • ✅ Electrical isolation – input to output

  • ✅ Reverse current prevention – battery to charger filter capacitor

  • ✅ Inrush current prevention – when connecting battery pack

  • ✅ Over current protection

  • ✅ Under voltage protection

  • ✅ Residual current protection

  • ✅ Surge protection

  • ✅ Leakage protection

  • ✅ Short circuit protection

  • ✅ Over temperature protection

  • ✅ Voltage withstand & insulation grade – meets all standards

  • ✅ EMC compliant


📐 Physical Dimensions & Installation

Item Specification
Cabinet Footprint 700 × 450 mm
Concrete Foundation Recommended 793 × 551 mm
Foundation Height ≥200 mm
Cable Inlet Bottom entry
Reserved Cable Length ≥700 mm
Installation Method Floor-mounted (ground)
Recommended Transport Forklift

Installation checklist (included):

Item Quantity
Ground-mounted DC EV Charger 1
Testing cards 2
Installation Instructions 1
Qualification Certificate 1
Expansion screws 4

Cable requirement (not included):

  • Cross-sectional area of DC input phase line, N line, and ground line: ≥35mm²


🖥️ Operation Interface

Display Area Instructions:

Button Function
0–9 Number input
Confirm Confirm operation
Return Return to previous interface
Delete Delete input box contents
Cancel Cancel operation

Charging Modes:

Mode Description
1. Automatic charging Smart charge until full
2. Charging by amount Set currency limit
3. Charging by energy Set kWh limit
4. Charging by time Set duration limit

Authentication Methods:

  • Password login (with verification code)

  • RFID card swipe

  • QR code scan (via APP)


⚙️ System Setup Menu (Professional Access)

Setting Description
Network settings IP address & port
Charger settings Consult technical personnel
Protection settings Over/under voltage, current, temperature
Rate settings Time-of-use pricing
Module settings Charging module information
Energy meter settings Meter parameters
RFID card settings Card & password management
Time settings System time
Charging record History query
Event record All system events
Charger testing Gun testing
Password settings System password change

📦 What’s Included

Item Quantity
ENC-DCL060A/B charger cabinet 1
CCS-2 connector(s) 1 or 2
Testing cards 2
Installation Instructions 1
Qualification Certificate 1
Expansion screws 4

🔧 Maintenance Requirements

  • ✅ Fix charger with anchor bolts – prevent tilting/vibration

  • ✅ Install shelter for outdoor units (shading & rain protection)

  • ✅ Regularly check bolt tightness & wire connections

  • ✅ Check for short circuits

  • ✅ Verify emergency stop button functionality

  • ✅ Ensure lightning protection & effective grounding

  • ✅ Operate within nominal voltage/current for maximum efficiency

  • ✅ After use: stop charging → wrap cable → return to holster

⚠️ Non-professionals are strictly forbidden to disassemble equipment components.


🚚 Storage & Transportation

Parameter Requirement
Packing Solid wooden box
Storage temp -25°C to +55°C
Storage humidity <80%
Storage environment Dry, clean, ventilated, no corrosive gases
Upside down Prohibited
Vibration/bumping Avoid – use tightening measures
Post-delivery Inspect for damage immediately